{"id":"CVE-2021-32009","state":"PUBLISHED","title":"Missing XSS guards on firmware page","description":"Cross-site Scripting (XSS) vulnerability in firmware section of Secomea GateManager allows logged in user to inject javascript in browser session. This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions.","publishedAt":"2022-03-11T17:53:58.000Z","updatedAt":"2024-08-03T23:17:28.154Z","severity":{"score":5,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L","source":"Secomea"},"assigner":"Secomea","products":["Secomea GateManager"],"affected":[{"vendor":"Secomea","product":"GateManager","versions":[{"version":"All","status":"affected","lessThanOrEqual":"9.6.621421014","versionType":"custom"}]}],"references":["https://www.secomea.com/support/cybersecurity-advisory"],"weaknesses":["CWE-79"],"ingestedAt":"2026-10-29T19:48:33.225Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2021/32xxx/CVE-2021-32009.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2021-32009","state":"PUBLISHED","datePublished":"2022-03-11T17:53:58.000Z","dateUpdated":"2024-08-03T23:17:28.154Z","assignerShortName":"Secomea","assignerOrgId":"f2815942-3388-4c08-ba09-6c15850fda90","dateReserved":"2021-05-03T00:00:00.000Z"},"containers":{"cna":{"title":"Missing XSS guards on firmware page","descriptions":[{"lang":"en","value":"Cross-site Scripting (XSS) vulnerability in firmware section of Secomea GateManager allows logged in user to inject javascript in browser session. This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions."}],"affected":[{"vendor":"Secomea","product":"GateManager","versions":[{"version":"All","status":"affected","lessThanOrEqual":"9.6.621421014","versionType":"custom"}]}],"references":[{"url":"https://www.secomea.com/support/cybersecurity-advisory","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":5,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79 Cross-site Scripting (XSS)","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Secomea","dateUpdated":"2022-03-11T17:53:58.000Z","orgId":"f2815942-3388-4c08-ba09-6c15850fda90"},"source":{"defect":["RD-5196"],"discovery":"INTERNAL"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"VulnerabilityReporting@secomea.com","ID":"CVE-2021-32009","STATE":"PUBLIC","TITLE":"Missing XSS guards on firmware page"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"GateManager","version":{"version_data":[{"version_affected":"<=","version_name":"All","version_value":"9.6.621421014"}]}}]},"vendor_name":"Secomea"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Cross-site Scripting (XSS) vulnerability in firmware section of Secomea GateManager allows logged in user to inject javascript in browser session. This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":5,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-79 Cross-site Scripting (XSS)"}]}]},"references":{"reference_data":[{"name":"https://www.secomea.com/support/cybersecurity-advisory","refsource":"MISC","url":"https://www.secomea.com/support/cybersecurity-advisory"}]},"source":{"defect":["RD-5196"],"discovery":"INTERNAL"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.secomea.com/support/cybersecurity-advisory","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T23:17:28.154Z"}}]}}}