{"id":"CVE-2021-31892","state":"PUBLISHED","title":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (A","description":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.","publishedAt":"2021-07-13T11:02:55.000Z","updatedAt":"2024-08-03T23:10:30.735Z","severity":null,"assigner":"siemens","products":["Siemens SINUMERIK Analyse MyCondition","Siemens SINUMERIK Analyze MyPerformance","Siemens SINUMERIK Analyze MyPerformance /OEE-Monitor","Siemens SINUMERIK Analyze MyPerformance /OEE-Tuning","Siemens SINUMERIK Integrate Client 02","Siemens SINUMERIK Integrate Client 03","Siemens SINUMERIK Integrate Client 04","Siemens SINUMERIK Integrate for Production 4.1","Siemens SINUMERIK Integrate for Production 5.1","Siemens SINUMERIK Manage MyMachines","Siemens SINUMERIK Manage MyMachines /Remote","Siemens SINUMERIK Manage MyMachines /Spindel Monitor","Siemens SINUMERIK Manage MyPrograms","Siemens SINUMERIK Manage MyResources /Programs","Siemens SINUMERIK Manage MyResources /Tools","Siemens SINUMERIK Manage MyTools","Siemens SINUMERIK Operate V4.8","Siemens SINUMERIK Operate V4.93","Siemens SINUMERIK Operate V4.94","Siemens SINUMERIK Optimize MyProgramming /NX-Cam Editor"],"affected":[{"vendor":"Siemens","product":"SINUMERIK Analyse MyCondition","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance /OEE-Monitor","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance /OEE-Tuning","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 02","versions":[{"version":"All versions >= V02.00.12 < 02.00.18","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 03","versions":[{"version":"All versions >= V03.00.12 < 03.00.18","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 04","versions":[{"version":"V04.00.02 and all versions >= V04.00.15 < 04.00.18","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate for Production 4.1","versions":[{"version":"All versions < V4.1 SP10 HF3","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate for Production 5.1","versions":[{"version":"V5.1","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines /Remote","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines /Spindel Monitor","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyPrograms","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyResources /Programs","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyResources /Tools","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyTools","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Operate V4.8","versions":[{"version":"All versions < V4.8 SP8","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Operate V4.93","versions":[{"version":"All versions < V4.93 HF7","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Operate V4.94","versions":[{"version":"All versions < V4.94 HF5","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Optimize MyProgramming /NX-Cam Editor","versions":[{"version":"All versions","status":"affected"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf","https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"],"weaknesses":["CWE-295"],"ingestedAt":"2026-10-29T19:48:30.098Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2021/31xxx/CVE-2021-31892.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2021-31892","state":"PUBLISHED","datePublished":"2021-07-13T11:02:55.000Z","dateUpdated":"2024-08-03T23:10:30.735Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2021-04-29T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario."}],"affected":[{"vendor":"Siemens","product":"SINUMERIK Analyse MyCondition","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance /OEE-Monitor","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Analyze MyPerformance /OEE-Tuning","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 02","versions":[{"version":"All versions >= V02.00.12 < 02.00.18","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 03","versions":[{"version":"All versions >= V03.00.12 < 03.00.18","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate Client 04","versions":[{"version":"V04.00.02 and all versions >= V04.00.15 < 04.00.18","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate for Production 4.1","versions":[{"version":"All versions < V4.1 SP10 HF3","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Integrate for Production 5.1","versions":[{"version":"V5.1","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines /Remote","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyMachines /Spindel Monitor","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyPrograms","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyResources /Programs","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyResources /Tools","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Manage MyTools","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Operate V4.8","versions":[{"version":"All versions < V4.8 SP8","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Operate V4.93","versions":[{"version":"All versions < V4.93 HF7","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Operate V4.94","versions":[{"version":"All versions < V4.94 HF5","status":"affected"}]},{"vendor":"Siemens","product":"SINUMERIK Optimize MyProgramming /NX-Cam Editor","versions":[{"version":"All versions","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf","tags":["x_refsource_MISC"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-295","description":"CWE-295: Improper Certificate Validation","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","dateUpdated":"2021-07-30T18:51:21.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2021-31892","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SINUMERIK Analyse MyCondition","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Analyze MyPerformance","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Analyze MyPerformance /OEE-Monitor","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Analyze MyPerformance /OEE-Tuning","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Integrate Client 02","version":{"version_data":[{"version_value":"All versions >= V02.00.12 < 02.00.18"}]}},{"product_name":"SINUMERIK Integrate Client 03","version":{"version_data":[{"version_value":"All versions >= V03.00.12 < 03.00.18"}]}},{"product_name":"SINUMERIK Integrate Client 04","version":{"version_data":[{"version_value":"V04.00.02 and all versions >= V04.00.15 < 04.00.18"}]}},{"product_name":"SINUMERIK Integrate for Production 4.1","version":{"version_data":[{"version_value":"All versions < V4.1 SP10 HF3"}]}},{"product_name":"SINUMERIK Integrate for Production 5.1","version":{"version_data":[{"version_value":"V5.1"}]}},{"product_name":"SINUMERIK Manage MyMachines","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyMachines /Remote","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyMachines /Spindel Monitor","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyPrograms","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyResources /Programs","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyResources /Tools","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Manage MyTools","version":{"version_data":[{"version_value":"All versions"}]}},{"product_name":"SINUMERIK Operate V4.8","version":{"version_data":[{"version_value":"All versions < V4.8 SP8"}]}},{"product_name":"SINUMERIK Operate V4.93","version":{"version_data":[{"version_value":"All versions < V4.93 HF7"}]}},{"product_name":"SINUMERIK Operate V4.94","version":{"version_data":[{"version_value":"All versions < V4.94 HF5"}]}},{"product_name":"SINUMERIK Optimize MyProgramming /NX-Cam Editor","version":{"version_data":[{"version_value":"All versions"}]}}]},"vendor_name":"Siemens"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-295: Improper Certificate Validation"}]}]},"references":{"reference_data":[{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf","refsource":"MISC","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf"},{"name":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04","refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-729965.pdf","tags":["x_refsource_MISC","x_transferred"]},{"url":"https://us-cert.cisa.gov/ics/advisories/icsa-21-194-04","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T23:10:30.735Z"}}]}}}