{"id":"CVE-2021-23855","state":"PUBLISHED","title":"Information disclosure","description":"The user and password data base is exposed by an unprotected web server resource. Passwords are hashed with a weak hashing algorithm and therefore allow an attacker to determine the password by using rainbow tables.","publishedAt":"2021-10-04T17:32:29.000Z","updatedAt":"2024-08-03T19:14:09.329Z","severity":{"score":8.6,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","source":"bosch"},"assigner":"bosch","products":["Rexroth IndraMotion MLC IndraMotion XLC"],"affected":[{"vendor":"Rexroth","product":"IndraMotion MLC IndraMotion XLC","versions":[{"version":"All","status":"affected"}]}],"references":["https://psirt.bosch.com/security-advisories/bosch-sa-741752.html"],"weaknesses":["CWE-200"],"ingestedAt":"2026-10-29T19:48:04.982Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2021/23xxx/CVE-2021-23855.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2021-23855","state":"PUBLISHED","datePublished":"2021-10-04T17:32:29.000Z","dateUpdated":"2024-08-03T19:14:09.329Z","assignerShortName":"bosch","assignerOrgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c","dateReserved":"2021-01-12T00:00:00.000Z"},"containers":{"cna":{"title":"Information disclosure","descriptions":[{"lang":"en","value":"The user and password data base is exposed by an unprotected web server resource. Passwords are hashed with a weak hashing algorithm and therefore allow an attacker to determine the password by using rainbow tables."}],"affected":[{"vendor":"Rexroth","product":"IndraMotion MLC IndraMotion XLC","versions":[{"version":"All","status":"affected"}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/bosch-sa-741752.html","tags":["x_refsource_CONFIRM"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.6,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-200","description":"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"bosch","dateUpdated":"2021-10-04T17:32:29.000Z","orgId":"c95f66b2-7e7c-41c5-8f09-6f86ec68659c"},"source":{"advisory":"BOSCH-SA-741752","discovery":"UNKNOWN"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"psirt@bosch.com","ID":"CVE-2021-23855","STATE":"PUBLIC","TITLE":"Information disclosure"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"IndraMotion MLC IndraMotion XLC","version":{"version_data":[{"version_affected":"=","version_value":"All"}]}}]},"vendor_name":"Rexroth"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"The user and password data base is exposed by an unprotected web server resource. Passwords are hashed with a weak hashing algorithm and therefore allow an attacker to determine the password by using rainbow tables."}]},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.6,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor"}]}]},"references":{"reference_data":[{"name":"https://psirt.bosch.com/security-advisories/bosch-sa-741752.html","refsource":"CONFIRM","url":"https://psirt.bosch.com/security-advisories/bosch-sa-741752.html"}]},"source":{"advisory":"BOSCH-SA-741752","discovery":"UNKNOWN"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://psirt.bosch.com/security-advisories/bosch-sa-741752.html","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T19:14:09.329Z"}}]}}}