{"id":"CVE-2021-22737","state":"PUBLISHED","title":"Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are dis","description":"Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.","publishedAt":"2021-05-26T00:00:00.000Z","updatedAt":"2024-08-03T18:51:06.979Z","severity":null,"assigner":"schneider","products":["n/a homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior"],"affected":[{"vendor":"n/a","product":"homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior","versions":[{"version":"homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior","status":"affected"}]}],"references":["https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04"],"weaknesses":["CWE-307"],"ingestedAt":"2026-10-29T19:48:02.192Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2021/22xxx/CVE-2021-22737.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2021-22737","state":"PUBLISHED","datePublished":"2021-05-26T00:00:00.000Z","dateUpdated":"2024-08-03T18:51:06.979Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2021-01-06T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack."}],"affected":[{"vendor":"n/a","product":"homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior","versions":[{"version":"homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior","status":"affected"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04"}],"problemTypes":[{"descriptions":[{"cweId":"CWE-307","type":"CWE","lang":"en","description":"CWE-307"}]}],"providerMetadata":{"shortName":"schneider","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateUpdated":"2022-11-10T00:00:00.000Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-04","tags":["x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-03T18:51:06.979Z"}}]}}}