{"id":"CVE-2020-8471","state":"PUBLISHED","title":"ABB Central Licensing System - Weak File Permissions","description":"For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code.","publishedAt":"2020-04-29T01:30:43.000Z","updatedAt":"2024-08-04T10:03:44.886Z","severity":{"score":7.8,"label":"High","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","source":"ABB"},"assigner":"ABB","products":["ABB Central Licensing System","ABB ABB Ability System 800xA","ABB Compact HMI","ABB Control Builder Safe","ABB Symphony Plus S+ Operations","ABB Symphony Plus S+ Engineering","ABB Composer Harmony","ABB Composer Melody","ABB Harmony OPC Server Standalone","ABB Advant OCS Control Builder A","ABB Composer CTK","ABB AdvaBuild","ABB OPC Server for Mod 300 (non-800xA)","ABB OPC Data Link","ABB Knowledge Manager","ABB Manufacturing Operations Management","ABB Advant  OCS AC 100 OPS Server"],"affected":[{"vendor":"ABB","product":"Central Licensing System","versions":[{"version":"5.1","status":"affected","lessThan":"5*","versionType":"custom"}]},{"vendor":"ABB","product":"ABB Ability System 800xA","versions":[{"version":"5.1","status":"affected"},{"version":"6.0","status":"affected"},{"version":"6.1","status":"affected"}]},{"vendor":"ABB","product":"Compact HMI","versions":[{"version":"5.1","status":"affected"},{"version":"6.0","status":"affected"}]},{"vendor":"ABB","product":"Control Builder Safe","versions":[{"version":"1.0","status":"affected"},{"version":"1.1","status":"affected"},{"version":"2.0","status":"affected"}]},{"vendor":"ABB","product":"Symphony Plus S+ Operations","versions":[{"version":"3","status":"affected","lessThanOrEqual":"3.2","versionType":"custom"}]},{"vendor":"ABB","product":"Symphony Plus S+ Engineering","versions":[{"version":"1.1","status":"affected","lessThanOrEqual":"2.2","versionType":"custom"}]},{"vendor":"ABB","product":"Composer Harmony","versions":[{"version":"5.1","status":"affected"},{"version":"6.0","status":"affected"},{"version":"6.1","status":"affected"}]},{"vendor":"ABB","product":"Composer Melody","versions":[{"version":"5.3","status":"affected"},{"version":"6","status":"affected","lessThanOrEqual":"6.3","versionType":"custom"}]},{"vendor":"ABB","product":"Harmony OPC Server Standalone","versions":[{"version":"6.0","status":"affected"},{"version":"6.1","status":"affected"},{"version":"7.0","status":"affected"}]},{"vendor":"ABB","product":"Advant OCS Control Builder A","versions":[{"version":"1.3","status":"affected"},{"version":"1.4","status":"affected"}]},{"vendor":"ABB","product":"Composer CTK","versions":[{"version":"6.1","status":"affected"},{"version":"6.2","status":"affected"}]},{"vendor":"ABB","product":"AdvaBuild","versions":[{"version":"3.7 SP1","status":"affected"},{"version":"3.7 SP2","status":"affected"}]},{"vendor":"ABB","product":"OPC Server for Mod 300 (non-800xA)","versions":[{"version":"1.4","status":"affected"}]},{"vendor":"ABB","product":"OPC Data Link","versions":[{"version":"2.1","status":"affected"},{"version":"2.2","status":"affected"}]},{"vendor":"ABB","product":"Knowledge Manager","versions":[{"version":"8.0","status":"affected"},{"version":"9.0","status":"affected"},{"version":"9.1","status":"affected"}]},{"vendor":"ABB","product":"Manufacturing Operations Management","versions":[{"version":"1812","status":"affected"},{"version":"1909","status":"affected"}]},{"vendor":"ABB","product":"Advant  OCS AC 100 OPS Server","versions":[{"version":"5.1","status":"affected"},{"version":"6.0","status":"affected"},{"version":"6.1","status":"affected"}]}],"references":["https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch","https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch","https://www.us-cert.gov/ics/advisories/icsa-20-154-04"],"weaknesses":["CWE-275"],"ingestedAt":"2026-10-29T19:47:44.297Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2020/8xxx/CVE-2020-8471.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2020-8471","state":"PUBLISHED","datePublished":"2020-04-29T01:30:43.000Z","dateUpdated":"2024-08-04T10:03:44.886Z","assignerShortName":"ABB","assignerOrgId":"2b718523-d88f-4f37-9bbd-300c20644bf9","dateReserved":"2020-01-30T00:00:00.000Z"},"containers":{"cna":{"title":"ABB Central Licensing System - Weak File Permissions","descriptions":[{"lang":"en","value":"For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code."}],"affected":[{"vendor":"ABB","product":"Central Licensing System","versions":[{"version":"5.1","status":"affected","lessThan":"5*","versionType":"custom"}]},{"vendor":"ABB","product":"ABB Ability System 800xA","versions":[{"version":"5.1","status":"affected"},{"version":"6.0","status":"affected"},{"version":"6.1","status":"affected"}]},{"vendor":"ABB","product":"Compact HMI","versions":[{"version":"5.1","status":"affected"},{"version":"6.0","status":"affected"}]},{"vendor":"ABB","product":"Control Builder Safe","versions":[{"version":"1.0","status":"affected"},{"version":"1.1","status":"affected"},{"version":"2.0","status":"affected"}]},{"vendor":"ABB","product":"Symphony Plus S+ Operations","versions":[{"version":"3","status":"affected","lessThanOrEqual":"3.2","versionType":"custom"}]},{"vendor":"ABB","product":"Symphony Plus S+ Engineering","versions":[{"version":"1.1","status":"affected","lessThanOrEqual":"2.2","versionType":"custom"}]},{"vendor":"ABB","product":"Composer Harmony","versions":[{"version":"5.1","status":"affected"},{"version":"6.0","status":"affected"},{"version":"6.1","status":"affected"}]},{"vendor":"ABB","product":"Composer Melody","versions":[{"version":"5.3","status":"affected"},{"version":"6","status":"affected","lessThanOrEqual":"6.3","versionType":"custom"}]},{"vendor":"ABB","product":"Harmony OPC Server Standalone","versions":[{"version":"6.0","status":"affected"},{"version":"6.1","status":"affected"},{"version":"7.0","status":"affected"}]},{"vendor":"ABB","product":"Advant OCS Control Builder A","versions":[{"version":"1.3","status":"affected"},{"version":"1.4","status":"affected"}]},{"vendor":"ABB","product":"Composer CTK","versions":[{"version":"6.1","status":"affected"},{"version":"6.2","status":"affected"}]},{"vendor":"ABB","product":"AdvaBuild","versions":[{"version":"3.7 SP1","status":"affected"},{"version":"3.7 SP2","status":"affected"}]},{"vendor":"ABB","product":"OPC Server for Mod 300 (non-800xA)","versions":[{"version":"1.4","status":"affected"}]},{"vendor":"ABB","product":"OPC Data Link","versions":[{"version":"2.1","status":"affected"},{"version":"2.2","status":"affected"}]},{"vendor":"ABB","product":"Knowledge Manager","versions":[{"version":"8.0","status":"affected"},{"version":"9.0","status":"affected"},{"version":"9.1","status":"affected"}]},{"vendor":"ABB","product":"Manufacturing Operations Management","versions":[{"version":"1812","status":"affected"},{"version":"1909","status":"affected"}]},{"vendor":"ABB","product":"Advant  OCS AC 100 OPS Server","versions":[{"version":"5.1","status":"affected"},{"version":"6.0","status":"affected"},{"version":"6.1","status":"affected"}]}],"references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_refsource_CONFIRM"]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_refsource_CONFIRM"]},{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-154-04","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-275","description":"CWE-275 Permission Issues","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"ABB","dateUpdated":"2020-06-09T16:16:51.000Z","orgId":"2b718523-d88f-4f37-9bbd-300c20644bf9"},"source":{"discovery":"UNKNOWN"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@ch.abb.com","ID":"CVE-2020-8471","STATE":"PUBLIC","TITLE":"ABB Central Licensing System - Weak File Permissions"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Central Licensing System","version":{"version_data":[{"version_affected":">=","version_name":"5","version_value":"5.1"}]}},{"product_name":"ABB Ability System 800xA","version":{"version_data":[{"version_affected":"=","version_value":"5.1"},{"version_affected":"=","version_value":"6.0"},{"version_affected":"=","version_value":"6.1"}]}},{"product_name":"Compact HMI","version":{"version_data":[{"version_affected":"=","version_value":"5.1"},{"version_affected":"=","version_value":"6.0"}]}},{"product_name":"Control Builder Safe","version":{"version_data":[{"version_affected":"=","version_value":"1.0"},{"version_affected":"=","version_value":"1.1"},{"version_affected":"=","version_value":"2.0"}]}},{"product_name":"Symphony Plus S+ Operations","version":{"version_data":[{"version_affected":"<=","version_name":"3","version_value":"3.2"}]}},{"product_name":"Symphony Plus S+ Engineering","version":{"version_data":[{"version_affected":"<=","version_name":"1.1","version_value":"2.2"}]}},{"product_name":"Composer Harmony","version":{"version_data":[{"version_affected":"=","version_value":"5.1"},{"version_affected":"=","version_value":"6.0"},{"version_affected":"=","version_value":"6.1"}]}},{"product_name":"Composer Melody","version":{"version_data":[{"version_affected":"=","version_value":"5.3"},{"version_affected":"<=","version_name":"6","version_value":"6.3"}]}},{"product_name":"Harmony OPC Server Standalone","version":{"version_data":[{"version_affected":"=","version_value":"6.0"},{"version_affected":"=","version_value":"6.1"},{"version_affected":"=","version_value":"7.0"}]}},{"product_name":"Advant OCS Control Builder A","version":{"version_data":[{"version_affected":"=","version_value":"1.3"},{"version_affected":"=","version_value":"1.4"}]}},{"product_name":"Composer CTK","version":{"version_data":[{"version_affected":"=","version_value":"6.1"},{"version_affected":"=","version_value":"6.2"}]}},{"product_name":"AdvaBuild","version":{"version_data":[{"version_affected":"=","version_value":"3.7 SP1"},{"version_affected":"=","version_value":"3.7 SP2"}]}},{"product_name":"OPC Server for Mod 300 (non-800xA)","version":{"version_data":[{"version_affected":"=","version_value":"1.4"}]}},{"product_name":"OPC Data Link","version":{"version_data":[{"version_affected":"=","version_value":"2.1"},{"version_affected":"=","version_value":"2.2"}]}},{"product_name":"Knowledge Manager","version":{"version_data":[{"version_affected":"=","version_value":"8.0"},{"version_affected":"=","version_value":"9.0"},{"version_affected":"=","version_value":"9.1"}]}},{"product_name":"Manufacturing Operations Management","version":{"version_data":[{"version_affected":"=","version_value":"1812"},{"version_affected":"=","version_value":"1909"}]}},{"product_name":"Advant  OCS AC 100 OPS Server","version":{"version_data":[{"version_affected":"=","version_value":"5.1"},{"version_affected":"=","version_value":"6.0"},{"version_affected":"=","version_value":"6.1"}]}}]},"vendor_name":"ABB"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"For the Central Licensing Server component used in ABB products ABB Ability™ System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability™ System 800xA/ Advant® OCS Control Builder A 1.3 and 1.4, Advant® OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, weak file permissions allow an authenticated attacker to block the license handling, escalate his/her privileges and execute arbitrary code."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-275 Permission Issues"}]}]},"references":{"reference_data":[{"name":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch","refsource":"CONFIRM","url":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch"},{"name":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch","refsource":"CONFIRM","url":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch"},{"name":"https://www.us-cert.gov/ics/advisories/icsa-20-154-04","refsource":"MISC","url":"https://www.us-cert.gov/ics/advisories/icsa-20-154-04"}]},"source":{"discovery":"UNKNOWN"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230&LanguageCode=en&DocumentPartId=&Action=Launch","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-154-04","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T10:03:44.886Z"}}]}}}