{"id":"CVE-2020-27282","state":"PUBLISHED","title":"In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an XML validation vulnerability in the ventilator allows privileged attackers with physical access to render the dev","description":"In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an XML validation vulnerability in the ventilator allows privileged attackers with physical access to render the device persistently unusable by uploading specially crafted configuration files.","publishedAt":"2021-03-15T21:21:54.000Z","updatedAt":"2024-08-04T16:11:36.603Z","severity":null,"assigner":"icscert","products":["n/a Hamilton Medical AG, T1-Ventillator"],"affected":[{"vendor":"n/a","product":"Hamilton Medical AG, T1-Ventillator","versions":[{"version":"Versions 2.2.3 and prior","status":"affected"}]}],"references":["https://us-cert.cisa.gov/ics/advisories/icsma-21-047-01"],"weaknesses":["CWE-112"],"ingestedAt":"2026-10-29T19:47:11.046Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2020/27xxx/CVE-2020-27282.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2020-27282","state":"PUBLISHED","datePublished":"2021-03-15T21:21:54.000Z","dateUpdated":"2024-08-04T16:11:36.603Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2020-10-19T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an XML validation vulnerability in the ventilator allows privileged attackers with physical access to render the device persistently unusable by uploading specially crafted configuration files."}],"affected":[{"vendor":"n/a","product":"Hamilton Medical AG, T1-Ventillator","versions":[{"version":"Versions 2.2.3 and prior","status":"affected"}]}],"references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-21-047-01","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-112","description":"MISSING XML VALIDATION CWE-112","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","dateUpdated":"2021-03-15T21:21:54.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2020-27282","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Hamilton Medical AG, T1-Ventillator","version":{"version_data":[{"version_value":"Versions 2.2.3 and prior"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, an XML validation vulnerability in the ventilator allows privileged attackers with physical access to render the device persistently unusable by uploading specially crafted configuration files."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"MISSING XML VALIDATION CWE-112"}]}]},"references":{"reference_data":[{"name":"https://us-cert.cisa.gov/ics/advisories/icsma-21-047-01","refsource":"MISC","url":"https://us-cert.cisa.gov/ics/advisories/icsma-21-047-01"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://us-cert.cisa.gov/ics/advisories/icsma-21-047-01","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T16:11:36.603Z"}}]}}}