{"id":"CVE-2020-25236","state":"PUBLISHED","title":"A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (A","description":"A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device\nexecuting the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset.","publishedAt":"2021-03-15T17:03:30.000Z","updatedAt":"2024-10-08T08:39:39.411Z","severity":{"score":5.5,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens LOGO! 12/24RCE","Siemens LOGO! 12/24RCEo","Siemens LOGO! 230RCE","Siemens LOGO! 230RCEo","Siemens LOGO! 24CE","Siemens LOGO! 24CEo","Siemens LOGO! 24RCE","Siemens LOGO! 24RCEo","Siemens SIPLUS LOGO! 12/24RCE","Siemens SIPLUS LOGO! 12/24RCEo","Siemens SIPLUS LOGO! 230RCE","Siemens SIPLUS LOGO! 230RCEo","Siemens SIPLUS LOGO! 24CE","Siemens SIPLUS LOGO! 24CEo","Siemens SIPLUS LOGO! 24RCE","Siemens SIPLUS LOGO! 24RCEo"],"affected":[{"vendor":"Siemens","product":"LOGO! 12/24RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 12/24RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 230RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 230RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 24CE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 24CEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 24RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 24RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 12/24RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 12/24RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 230RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 230RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24CE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24CEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf","https://cert-portal.siemens.com/productcert/html/ssa-783481.html"],"weaknesses":["CWE-755"],"ingestedAt":"2026-10-29T19:47:05.429Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2020/25xxx/CVE-2020-25236.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2020-25236","state":"PUBLISHED","datePublished":"2021-03-15T17:03:30.000Z","dateUpdated":"2024-10-08T08:39:39.411Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2020-09-10T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). The control logic (CL) the LOGO! 8 executes could be manipulated in a way that could cause the device\nexecuting the CL to improperly handle the manipulation and crash. After successful execution of the attack, the device needs to be manually reset."}],"affected":[{"vendor":"Siemens","product":"LOGO! 12/24RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 12/24RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 230RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 230RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 24CE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 24CEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 24RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"LOGO! 24RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 12/24RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 12/24RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 230RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 230RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24CE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24CEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24RCE","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]},{"vendor":"Siemens","product":"SIPLUS LOGO! 24RCEo","defaultStatus":"unknown","versions":[{"version":"0","status":"affected","lessThan":"*","versionType":"custom"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf","tags":["x_refsource_MISC"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-783481.html"}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:T/RC:C","baseScore":5.5,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-755","lang":"en","description":"CWE-755: Improper Handling of Exceptional Conditions","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-10-08T08:39:39.411Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T15:33:05.207Z"}}]}}}