{"id":"CVE-2020-12036","state":"PUBLISHED","title":"Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatmen","description":"Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device.","publishedAt":"2020-06-29T13:49:53.000Z","updatedAt":"2024-08-04T11:48:57.981Z","severity":null,"assigner":"icscert","products":["n/a Baxter PrismaFlex and PrisMax"],"affected":[{"vendor":"n/a","product":"Baxter PrismaFlex and PrisMax","versions":[{"version":"PrismaFlex all versions, PrisMax all versions prior to 3.x","status":"affected"}]}],"references":["https://www.us-cert.gov/ics/advisories/icsma-20-170-01"],"weaknesses":["CWE-319"],"ingestedAt":"2026-10-29T19:46:27.697Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2020/12xxx/CVE-2020-12036.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2020-12036","state":"PUBLISHED","datePublished":"2020-06-29T13:49:53.000Z","dateUpdated":"2024-08-04T11:48:57.981Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2020-04-21T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device."}],"affected":[{"vendor":"n/a","product":"Baxter PrismaFlex and PrisMax","versions":[{"version":"PrismaFlex all versions, PrisMax all versions prior to 3.x","status":"affected"}]}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsma-20-170-01","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-319","description":"CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","dateUpdated":"2020-06-29T13:49:53.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2020-12036","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Baxter PrismaFlex and PrisMax","version":{"version_data":[{"version_value":"PrismaFlex all versions, PrisMax all versions prior to 3.x"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CLEARTEXT TRANSMISSION OF SENSITIVE INFORMATION CWE-319"}]}]},"references":{"reference_data":[{"name":"https://www.us-cert.gov/ics/advisories/icsma-20-170-01","refsource":"MISC","url":"https://www.us-cert.gov/ics/advisories/icsma-20-170-01"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.us-cert.gov/ics/advisories/icsma-20-170-01","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T11:48:57.981Z"}}]}}}