{"id":"CVE-2020-10613","state":"PUBLISHED","title":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper vali","description":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.","publishedAt":"2020-04-15T18:30:42.000Z","updatedAt":"2024-08-04T11:06:10.142Z","severity":null,"assigner":"icscert","products":["n/a Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122"],"affected":[{"vendor":"n/a","product":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","versions":[{"version":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","status":"affected"}]}],"references":["https://www.us-cert.gov/ics/advisories/icsa-20-105-03","https://www.zerodayinitiative.com/advisories/ZDI-20-548/"],"weaknesses":["CWE-125"],"ingestedAt":"2026-10-29T19:46:21.897Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2020/10xxx/CVE-2020-10613.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2020-10613","state":"PUBLISHED","datePublished":"2020-04-15T18:30:42.000Z","dateUpdated":"2024-08-04T11:06:10.142Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2020-03-16T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets."}],"affected":[{"vendor":"n/a","product":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","versions":[{"version":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","status":"affected"}]}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-105-03","tags":["x_refsource_MISC"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-548/","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-125","description":"OUT-OF-BOUNDS READ CWE-125","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","dateUpdated":"2020-04-16T18:06:05.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2020-10613","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","version":{"version_data":[{"version_value":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"OUT-OF-BOUNDS READ CWE-125"}]}]},"references":{"reference_data":[{"name":"https://www.us-cert.gov/ics/advisories/icsa-20-105-03","refsource":"MISC","url":"https://www.us-cert.gov/ics/advisories/icsa-20-105-03"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-20-548/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-20-548/"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-105-03","tags":["x_refsource_MISC","x_transferred"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-20-548/","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T11:06:10.142Z"}}]}}}