{"id":"CVE-2020-10268","state":"PUBLISHED","title":"RVD#2550: Terminate Critical Services in KUKA controller KR C4","description":"Critical services for operation can be terminated from windows task manager, bringing the manipulator to a halt. After this a Re-Calibration of the brakes needs to be performed. Be noted that this only can be accomplished either by a Kuka technician or by Kuka issued calibration hardware that interfaces with the manipulator furthering the delay and increasing operational costs.","publishedAt":"2020-06-16T17:55:11.700Z","updatedAt":"2024-09-16T18:59:43.071Z","severity":null,"assigner":"Alias","products":["KUKA Roboter GmbH KR3R540, KRC4, KSS8.5.7HF1, Win7_Embedded"],"affected":[{"vendor":"KUKA Roboter GmbH","product":"KR3R540, KRC4, KSS8.5.7HF1, Win7_Embedded","versions":[{"version":"unspecified","status":"affected"}]}],"references":["https://github.com/aliasrobotics/RVD/issues/2550"],"weaknesses":["CWE-749"],"ingestedAt":"2026-10-29T19:46:21.897Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2020/10xxx/CVE-2020-10268.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2020-10268","state":"PUBLISHED","datePublished":"2020-06-16T17:55:11.700Z","dateUpdated":"2024-09-16T18:59:43.071Z","assignerShortName":"Alias","assignerOrgId":"dc524f69-879d-41dc-ab8f-724e78658a1a","dateReserved":"2020-03-10T00:00:00.000Z"},"containers":{"cna":{"title":"RVD#2550: Terminate Critical Services in KUKA controller KR C4","descriptions":[{"lang":"en","value":"Critical services for operation can be terminated from windows task manager, bringing the manipulator to a halt. After this a Re-Calibration of the brakes needs to be performed. Be noted that this only can be accomplished either by a Kuka technician or by Kuka issued calibration hardware that interfaces with the manipulator furthering the delay and increasing operational costs."}],"affected":[{"vendor":"KUKA Roboter GmbH","product":"KR3R540, KRC4, KSS8.5.7HF1, Win7_Embedded","versions":[{"version":"unspecified","status":"affected"}]}],"references":[{"url":"https://github.com/aliasrobotics/RVD/issues/2550","tags":["x_refsource_CONFIRM"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-749","description":"CWE-749","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"Alias","dateUpdated":"2020-06-16T17:55:11.000Z","orgId":"dc524f69-879d-41dc-ab8f-724e78658a1a"},"credits":[{"lang":"en","value":"Alias Robotics (group, https://aliasrobotics.com)"}],"datePublic":"2020-06-16T00:00:00.000Z","source":{"defect":["RVD#2550"],"discovery":"EXTERNAL"},"x_ConverterErrors":{"cvssV3_0":{"error":"CVSSV3_0 data from v4 record is invalid","message":"Malformed CVSS3 vector, trailing \"/\""}},"x_generator":{"engine":"Robot Vulnerability Database (RVD)"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@aliasrobotics.com","DATE_PUBLIC":"2020-06-16T17:49:11 +00:00","ID":"CVE-2020-10268","STATE":"PUBLIC","TITLE":"RVD#2550: Terminate Critical Services in KUKA controller KR C4"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"KR3R540, KRC4, KSS8.5.7HF1, Win7_Embedded","version":{"version_data":[{"version_value":""}]}}]},"vendor_name":"KUKA Roboter GmbH"}]}},"credit":[{"lang":"eng","value":"Alias Robotics (group, https://aliasrobotics.com)"}],"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Critical services for operation can be terminated from windows task manager, bringing the manipulator to a halt. After this a Re-Calibration of the brakes needs to be performed. Be noted that this only can be accomplished either by a Kuka technician or by Kuka issued calibration hardware that interfaces with the manipulator furthering the delay and increasing operational costs."}]},"generator":{"engine":"Robot Vulnerability Database (RVD)"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"HIGH","baseScore":6.1,"baseSeverity":"medium","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H/","version":"3.0"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-749"}]}]},"references":{"reference_data":[{"name":"https://github.com/aliasrobotics/RVD/issues/2550","refsource":"CONFIRM","url":"https://github.com/aliasrobotics/RVD/issues/2550"}]},"source":{"defect":["RVD#2550"],"discovery":"EXTERNAL"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://github.com/aliasrobotics/RVD/issues/2550","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T10:58:40.108Z"}}]}}}