{"id":"CVE-2019-6846","state":"PUBLISHED","title":"A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which coul","description":"A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol.","publishedAt":"2019-10-29T14:51:31.000Z","updatedAt":"2024-08-04T20:31:04.392Z","severity":null,"assigner":"schneider","products":["n/a Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)"],"affected":[{"vendor":"n/a","product":"Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)","versions":[{"version":"Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)","status":"affected"}]}],"references":["https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02"],"weaknesses":["CWE-319"],"ingestedAt":"2026-10-29T19:46:06.737Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2019/6xxx/CVE-2019-6846.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2019-6846","state":"PUBLISHED","datePublished":"2019-10-29T14:51:31.000Z","dateUpdated":"2024-08-04T20:31:04.392Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2019-01-25T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol."}],"affected":[{"vendor":"n/a","product":"Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)","versions":[{"version":"Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)","status":"affected"}]}],"references":[{"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02","tags":["x_refsource_CONFIRM"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-319","description":"CWE-319: Cleartext Transmission of Sensitive Information","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","dateUpdated":"2019-10-29T14:51:31.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2019-6846","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)","version":{"version_data":[{"version_value":"Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions)"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists in Modicon M580, Modicon M340, Modicon BMxCRA and 140CRA modules (all firmware versions), which could cause information disclosure when using the FTP protocol."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-319: Cleartext Transmission of Sensitive Information"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02","refsource":"CONFIRM","url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-281-02","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T20:31:04.392Z"}}]}}}