{"id":"CVE-2019-6536","state":"PUBLISHED","title":"Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code","description":"Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process.","publishedAt":"2019-03-27T15:25:23.000Z","updatedAt":"2024-08-04T20:23:21.362Z","severity":null,"assigner":"icscert","products":["LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME LAquis SCADA"],"affected":[{"vendor":"LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME","product":"LAquis SCADA","versions":[{"version":"< 4.3.1.71","status":"affected"}]}],"references":["https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01","https://www.zerodayinitiative.com/advisories/ZDI-19-307/"],"weaknesses":["CWE-787"],"ingestedAt":"2026-10-29T19:46:06.737Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2019/6xxx/CVE-2019-6536.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2019-6536","state":"PUBLISHED","datePublished":"2019-03-27T15:25:23.000Z","dateUpdated":"2024-08-04T20:23:21.362Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2019-01-22T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process."}],"affected":[{"vendor":"LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME","product":"LAquis SCADA","versions":[{"version":"< 4.3.1.71","status":"affected"}]}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01","tags":["x_refsource_MISC"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-787","description":"Out-of-Bounds Write CWE-787","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","dateUpdated":"2019-04-02T15:06:09.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6"},"datePublic":"2019-03-14T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2019-6536","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"LAquis SCADA","version":{"version_data":[{"version_value":"< 4.3.1.71"}]}}]},"vendor_name":"LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Out-of-Bounds Write CWE-787"}]}]},"references":{"reference_data":[{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01","tags":["x_refsource_MISC","x_transferred"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T20:23:21.362Z"}}]}}}