{"id":"CVE-2019-5165","state":"PUBLISHED","title":"An exploitable authentication bypass vulnerability exists in the hostname processing of the Moxa AWK-3131A firmware version 1.13. A specially configured device hostname can cause t","description":"An exploitable authentication bypass vulnerability exists in the hostname processing of the Moxa AWK-3131A firmware version 1.13. A specially configured device hostname can cause the device to interpret select remote traffic as local traffic, resulting in a bypass of web authentication. An attacker can send authenticated SNMP requests to trigger this vulnerability.","publishedAt":"2020-02-25T15:49:11.000Z","updatedAt":"2024-08-04T19:47:56.584Z","severity":{"score":8,"label":"High","version":"3.0","vector":"CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H","source":"talos"},"assigner":"talos","products":["n/a Moxa"],"affected":[{"vendor":"n/a","product":"Moxa","versions":[{"version":"Moxa AWK-3131A Firmware version 1.13","status":"affected"}]}],"references":["https://talosintelligence.com/vulnerability_reports/TALOS-2019-0960"],"weaknesses":["CWE-288"],"ingestedAt":"2026-10-29T19:46:04.126Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2019/5xxx/CVE-2019-5165.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2019-5165","state":"PUBLISHED","datePublished":"2020-02-25T15:49:11.000Z","dateUpdated":"2024-08-04T19:47:56.584Z","assignerShortName":"talos","assignerOrgId":"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b","dateReserved":"2019-01-04T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"An exploitable authentication bypass vulnerability exists in the hostname processing of the Moxa AWK-3131A firmware version 1.13. A specially configured device hostname can cause the device to interpret select remote traffic as local traffic, resulting in a bypass of web authentication. An attacker can send authenticated SNMP requests to trigger this vulnerability."}],"affected":[{"vendor":"n/a","product":"Moxa","versions":[{"version":"Moxa AWK-3131A Firmware version 1.13","status":"affected"}]}],"references":[{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0960","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_0":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-288","description":"CWE-288: Authentication Bypass Using an Alternate Path or Channel","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"talos","dateUpdated":"2022-04-19T17:35:05.000Z","orgId":"b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"talos-cna@cisco.com","ID":"CVE-2019-5165","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Moxa","version":{"version_data":[{"version_value":"Moxa AWK-3131A Firmware version 1.13"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An exploitable authentication bypass vulnerability exists in the hostname processing of the Moxa AWK-3131A firmware version 1.13. A specially configured device hostname can cause the device to interpret select remote traffic as local traffic, resulting in a bypass of web authentication. An attacker can send authenticated SNMP requests to trigger this vulnerability."}]},"impact":{"cvss":{"baseScore":8,"baseSeverity":"High","vectorString":"CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H","version":"3.0"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-288: Authentication Bypass Using an Alternate Path or Channel"}]}]},"references":{"reference_data":[{"name":"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0960","refsource":"MISC","url":"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0960"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2019-0960","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T19:47:56.584Z"}}]}}}