{"id":"CVE-2019-3733","state":"PUBLISHED","title":"RSA BSAFE Crypto-C Micro Edition, all versions prior to 4.1.4, is vulnerable to three (3) different Improper Clearing of Heap Memory Before Release vulnerability, also known as 'He","description":"RSA BSAFE Crypto-C Micro Edition, all versions prior to 4.1.4, is vulnerable to three (3) different Improper Clearing of Heap Memory Before Release vulnerability, also known as 'Heap Inspection vulnerability'. A malicious remote user could potentially exploit this vulnerability to extract information leaving data at risk of exposure.","publishedAt":"2019-09-30T21:48:40.378Z","updatedAt":"2024-09-16T23:20:53.121Z","severity":{"score":4.4,"label":"Medium","version":"3.0","vector":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","source":"dell"},"assigner":"dell","products":["Dell RSA BSAFE Crypto-C Micro Edition","Dell RSA BSAFE MES"],"affected":[{"vendor":"Dell","product":"RSA BSAFE Crypto-C Micro Edition","versions":[{"version":"unspecified","status":"affected","lessThan":"4.1.4","versionType":"custom"}]},{"vendor":"Dell","product":"RSA BSAFE MES","versions":[{"version":"unspecified","status":"affected","lessThan":"4.4","versionType":"custom"}]}],"references":["https://www.dell.com/support/kbdoc/000194054"],"weaknesses":["CWE-316"],"ingestedAt":"2026-10-29T19:45:59.128Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2019/3xxx/CVE-2019-3733.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2019-3733","state":"PUBLISHED","datePublished":"2019-09-30T21:48:40.378Z","dateUpdated":"2024-09-16T23:20:53.121Z","assignerShortName":"dell","assignerOrgId":"c550e75a-17ff-4988-97f0-544cde3820fe","dateReserved":"2019-01-03T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"RSA BSAFE Crypto-C Micro Edition, all versions prior to 4.1.4, is vulnerable to three (3) different Improper Clearing of Heap Memory Before Release vulnerability, also known as 'Heap Inspection vulnerability'. A malicious remote user could potentially exploit this vulnerability to extract information leaving data at risk of exposure."}],"affected":[{"vendor":"Dell","product":"RSA BSAFE Crypto-C Micro Edition","versions":[{"version":"unspecified","status":"affected","lessThan":"4.1.4","versionType":"custom"}]},{"vendor":"Dell","product":"RSA BSAFE MES","versions":[{"version":"unspecified","status":"affected","lessThan":"4.4","versionType":"custom"}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/000194054","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_0":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":4.4,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","version":"3.0"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-316","description":"CWE-316: Cleartext Storage of Sensitive Information in Memory","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"dell","dateUpdated":"2022-02-04T22:32:52.000Z","orgId":"c550e75a-17ff-4988-97f0-544cde3820fe"},"datePublic":"2019-09-12T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"secure@dell.com","DATE_PUBLIC":"2019-09-12","ID":"CVE-2019-3733","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"RSA BSAFE Crypto-C Micro Edition","version":{"version_data":[{"version_affected":"<","version_value":"4.1.4"}]}},{"product_name":"RSA BSAFE MES","version":{"version_data":[{"version_affected":"<","version_value":"4.4"}]}}]},"vendor_name":"Dell"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"RSA BSAFE Crypto-C Micro Edition, all versions prior to 4.1.4, is vulnerable to three (3) different Improper Clearing of Heap Memory Before Release vulnerability, also known as 'Heap Inspection vulnerability'. A malicious remote user could potentially exploit this vulnerability to extract information leaving data at risk of exposure."}]},"impact":{"cvss":{"baseScore":4.4,"baseSeverity":"Medium","vectorString":"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","version":"3.0"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-316: Cleartext Storage of Sensitive Information in Memory"}]}]},"references":{"reference_data":[{"name":"https://www.dell.com/support/kbdoc/000194054","refsource":"MISC","url":"https://www.dell.com/support/kbdoc/000194054"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.dell.com/support/kbdoc/000194054","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T19:19:18.281Z"}}]}}}