{"id":"CVE-2019-19295","state":"PUBLISHED","title":"A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of","description":"A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of\nsecurity-relevant activities in its XML-based communication protocol\nas provided by default on ports 5444/tcp and 5440/tcp.\nAn authenticated remote attacker could exploit this vulnerability to\nperform covert actions that are not visible in the application log.","publishedAt":"2020-03-10T19:16:17.000Z","updatedAt":"2024-11-18T17:47:21.496Z","severity":{"score":4.3,"label":"Medium","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:U/RC:C","source":"siemens"},"assigner":"siemens","products":["Siemens Control Center Server (CCS)"],"affected":[{"vendor":"Siemens","product":"Control Center Server (CCS)","defaultStatus":"unknown","versions":[{"version":"All versions < V1.5.0","status":"affected"}]}],"references":["https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf","https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"],"weaknesses":["CWE-778"],"ingestedAt":"2026-10-29T19:45:43.853Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2019/19xxx/CVE-2019-19295.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2019-19295","state":"PUBLISHED","datePublished":"2020-03-10T19:16:17.000Z","dateUpdated":"2024-11-18T17:47:21.496Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2019-11-26T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) does not enforce logging of\nsecurity-relevant activities in its XML-based communication protocol\nas provided by default on ports 5444/tcp and 5440/tcp.\nAn authenticated remote attacker could exploit this vulnerability to\nperform covert actions that are not visible in the application log."}],"affected":[{"vendor":"Siemens","product":"Control Center Server (CCS)","defaultStatus":"unknown","versions":[{"version":"All versions < V1.5.0","status":"affected"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf","tags":["x_refsource_MISC"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf","tags":["x_refsource_CONFIRM"]}],"metrics":[{"cvssV3_1":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N/E:P/RL:U/RC:C","baseScore":4.3,"baseSeverity":"MEDIUM"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-778","lang":"en","description":"CWE-778: Insufficient Logging","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateUpdated":"2024-01-09T09:56:24.293Z"}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf","tags":["x_refsource_MISC","x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T02:09:39.659Z"}},{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2024-01-16T20:19:51.942522Z","id":"CVE-2019-19295","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2024-11-18T17:47:21.496Z"}}]}}}