{"id":"CVE-2019-13935","state":"PUBLISHED","title":"Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflecte","description":"Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.","publishedAt":"2019-11-27T13:30:16.631Z","updatedAt":"2024-09-17T01:11:21.790Z","severity":{"score":3.5,"label":"Low","version":"3.1","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N","source":"siemens"},"assigner":"siemens","products":["Siemens AG Polarion"],"affected":[{"vendor":"Siemens AG","product":"Polarion","versions":[{"version":"All versions < 19.2","status":"affected"}]}],"references":["https://xavibel.com/2019/11/25/siemens-polarion-multiple-web-vulnerabilities/"],"weaknesses":["CWE-79"],"ingestedAt":"2026-10-29T19:45:27.952Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2019/13xxx/CVE-2019-13935.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2019-13935","state":"PUBLISHED","datePublished":"2019-11-27T13:30:16.631Z","dateUpdated":"2024-09-17T01:11:21.790Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2019-07-18T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2."}],"affected":[{"vendor":"Siemens AG","product":"Polarion","versions":[{"version":"All versions < 19.2","status":"affected"}]}],"references":[{"url":"https://xavibel.com/2019/11/25/siemens-polarion-multiple-web-vulnerabilities/","tags":["x_refsource_MISC"]}],"metrics":[{"cvssV3_1":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":3.5,"baseSeverity":"LOW","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N","version":"3.1"}}],"problemTypes":[{"descriptions":[{"cweId":"CWE-79","description":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","dateUpdated":"2019-11-27T13:30:16.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77"},"datePublic":"2019-11-26T00:00:00.000Z","source":{"discovery":"EXTERNAL"},"x_generator":{"engine":"Vulnogram 0.0.9"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","DATE_PUBLIC":"2019-11-26T00:00:00.000Z","ID":"CVE-2019-13935","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Polarion","version":{"version_data":[{"version_value":"All versions < 19.2"}]}}]},"vendor_name":"Siemens AG"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a reflected XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2."}]},"generator":{"engine":"Vulnogram 0.0.9"},"impact":{"cvss":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":3.5,"baseSeverity":"LOW","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N","version":"3.1"}},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"}]}]},"references":{"reference_data":[{"name":"https://xavibel.com/2019/11/25/siemens-polarion-multiple-web-vulnerabilities/","refsource":"MISC","url":"https://xavibel.com/2019/11/25/siemens-polarion-multiple-web-vulnerabilities/"}]},"source":{"discovery":"EXTERNAL"}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://xavibel.com/2019/11/25/siemens-polarion-multiple-web-vulnerabilities/","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T00:05:44.006Z"}}]}}}