{"id":"CVE-2019-13514","state":"PUBLISHED","title":"In Delta Industrial Automation DOPSoft, Version 4.00.06.15 and prior, processing a specially crafted project file may trigger a use-after-free vulnerability, which may allow inform","description":"In Delta Industrial Automation DOPSoft, Version 4.00.06.15 and prior, processing a specially crafted project file may trigger a use-after-free vulnerability, which may allow information disclosure, remote code execution, or crash of the application.","publishedAt":"2019-08-15T18:42:51.000Z","updatedAt":"2024-08-04T23:57:39.174Z","severity":null,"assigner":"icscert","products":["n/a Delta Industrial Automation DOPSoft"],"affected":[{"vendor":"n/a","product":"Delta Industrial Automation DOPSoft","versions":[{"version":"Version 4.00.06.15 and prior.","status":"affected"}]}],"references":["https://www.us-cert.gov/ics/advisories/icsa-19-225-01","https://www.zerodayinitiative.com/advisories/ZDI-19-717/"],"weaknesses":["CWE-416"],"ingestedAt":"2026-10-29T19:45:27.952Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2019/13xxx/CVE-2019-13514.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2019-13514","state":"PUBLISHED","datePublished":"2019-08-15T18:42:51.000Z","dateUpdated":"2024-08-04T23:57:39.174Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2019-07-11T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"In Delta Industrial Automation DOPSoft, Version 4.00.06.15 and prior, processing a specially crafted project file may trigger a use-after-free vulnerability, which may allow information disclosure, remote code execution, or crash of the application."}],"affected":[{"vendor":"n/a","product":"Delta Industrial Automation DOPSoft","versions":[{"version":"Version 4.00.06.15 and prior.","status":"affected"}]}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-19-225-01","tags":["x_refsource_MISC"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-717/","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-416","description":"USE AFTER FREE CWE-416","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","dateUpdated":"2019-08-16T09:06:11.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2019-13514","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Delta Industrial Automation DOPSoft","version":{"version_data":[{"version_value":"Version 4.00.06.15 and prior."}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Delta Industrial Automation DOPSoft, Version 4.00.06.15 and prior, processing a specially crafted project file may trigger a use-after-free vulnerability, which may allow information disclosure, remote code execution, or crash of the application."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"USE AFTER FREE CWE-416"}]}]},"references":{"reference_data":[{"name":"https://www.us-cert.gov/ics/advisories/icsa-19-225-01","refsource":"MISC","url":"https://www.us-cert.gov/ics/advisories/icsa-19-225-01"},{"name":"https://www.zerodayinitiative.com/advisories/ZDI-19-717/","refsource":"MISC","url":"https://www.zerodayinitiative.com/advisories/ZDI-19-717/"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-19-225-01","tags":["x_refsource_MISC","x_transferred"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-717/","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-04T23:57:39.174Z"}}]}}}