{"id":"CVE-2018-7820","state":"PUBLISHED","title":"A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext","description":"A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.","publishedAt":"2019-09-17T19:45:32.000Z","updatedAt":"2024-08-05T06:37:59.195Z","severity":null,"assigner":"schneider","products":["Schneider Electric SE APC UPS Network Management Card 2 AOS"],"affected":[{"vendor":"Schneider Electric SE","product":"APC UPS Network Management Card 2 AOS","versions":[{"version":"v6.5.6","status":"affected"}]}],"references":["https://www.apc.com/salestools/CCON-BFQMXC/CCON-BFQMXC_R0_EN.pdf"],"weaknesses":["CWE-255"],"ingestedAt":"2026-10-29T19:45:00.684Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2018/7xxx/CVE-2018-7820.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2018-7820","state":"PUBLISHED","datePublished":"2019-09-17T19:45:32.000Z","dateUpdated":"2024-08-05T06:37:59.195Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2018-03-08T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled."}],"affected":[{"vendor":"Schneider Electric SE","product":"APC UPS Network Management Card 2 AOS","versions":[{"version":"v6.5.6","status":"affected"}]}],"references":[{"url":"https://www.apc.com/salestools/CCON-BFQMXC/CCON-BFQMXC_R0_EN.pdf","tags":["x_refsource_CONFIRM"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-255","description":"CWE-255:Credentials Management","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"schneider","dateUpdated":"2019-09-17T19:45:32.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2018-7820","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"APC UPS Network Management Card 2 AOS","version":{"version_data":[{"version_value":"v6.5.6"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-255:Credentials Management"}]}]},"references":{"reference_data":[{"name":"https://www.apc.com/salestools/CCON-BFQMXC/CCON-BFQMXC_R0_EN.pdf","refsource":"CONFIRM","url":"https://www.apc.com/salestools/CCON-BFQMXC/CCON-BFQMXC_R0_EN.pdf"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.apc.com/salestools/CCON-BFQMXC/CCON-BFQMXC_R0_EN.pdf","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T06:37:59.195Z"}}]}}}