{"id":"CVE-2018-7812","state":"PUBLISHED","title":"An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends di","description":"An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses in a way that exposes security-relevant information about the state of the product, such as whether a particular operation was successful or not.","publishedAt":"2018-12-17T22:00:00.000Z","updatedAt":"2024-08-05T06:37:59.305Z","severity":null,"assigner":"schneider","products":["Schneider Electric SE Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200"],"affected":[{"vendor":"Schneider Electric SE","product":"Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","versions":[{"version":"Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","status":"affected"}]}],"references":["https://github.com/SadFud/Exploits/tree/master/Real%20World/SCADA%20-%20IOT%20Systems/CVE-2018-7812","https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/"],"weaknesses":[],"ingestedAt":"2026-10-29T19:45:00.684Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2018/7xxx/CVE-2018-7812.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2018-7812","state":"PUBLISHED","datePublished":"2018-12-17T22:00:00.000Z","dateUpdated":"2024-08-05T06:37:59.305Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2018-03-08T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses in a way that exposes security-relevant information about the state of the product, such as whether a particular operation was successful or not."}],"affected":[{"vendor":"Schneider Electric SE","product":"Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","versions":[{"version":"Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","status":"affected"}]}],"references":[{"url":"https://github.com/SadFud/Exploits/tree/master/Real%20World/SCADA%20-%20IOT%20Systems/CVE-2018-7812","tags":["x_refsource_MISC"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/","tags":["x_refsource_CONFIRM"]}],"problemTypes":[{"descriptions":[{"description":"Information Exposure Through Discrepancy","lang":"en","type":"text"}]}],"providerMetadata":{"shortName":"schneider","dateUpdated":"2018-12-21T21:57:01.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb"},"datePublic":"2018-12-17T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","ID":"CVE-2018-7812","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200","version":{"version_data":[{"version_value":"Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"An Information Exposure through Discrepancy vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where the web server sends different responses in a way that exposes security-relevant information about the state of the product, such as whether a particular operation was successful or not."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Information Exposure Through Discrepancy"}]}]},"references":{"reference_data":[{"name":"https://github.com/SadFud/Exploits/tree/master/Real%20World/SCADA%20-%20IOT%20Systems/CVE-2018-7812","refsource":"MISC","url":"https://github.com/SadFud/Exploits/tree/master/Real%20World/SCADA%20-%20IOT%20Systems/CVE-2018-7812"},{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://github.com/SadFud/Exploits/tree/master/Real%20World/SCADA%20-%20IOT%20Systems/CVE-2018-7812","tags":["x_refsource_MISC","x_transferred"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-327-01/","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T06:37:59.305Z"}}]}}}