{"id":"CVE-2018-7522","state":"PUBLISHED","title":"In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in ","description":"In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states.","publishedAt":"2018-05-04T17:00:00.000Z","updatedAt":"2024-09-17T00:02:25.672Z","severity":null,"assigner":"icscert","products":["Schneider Electric Triconex Tricon"],"affected":[{"vendor":"Schneider Electric","product":"Triconex Tricon","versions":[{"version":"MP model 3008 firmware versions 10.0-10.4","status":"affected"}]}],"references":["https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/","https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02","http://www.securityfocus.com/bid/103947"],"weaknesses":["CWE-119"],"ingestedAt":"2026-10-29T19:45:00.684Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2018/7xxx/CVE-2018-7522.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2018-7522","state":"PUBLISHED","datePublished":"2018-05-04T17:00:00.000Z","dateUpdated":"2024-09-17T00:02:25.672Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2018-02-26T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states."}],"affected":[{"vendor":"Schneider Electric","product":"Triconex Tricon","versions":[{"version":"MP model 3008 firmware versions 10.0-10.4","status":"affected"}]}],"references":[{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/","tags":["x_refsource_CONFIRM"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02","tags":["x_refsource_MISC"]},{"url":"http://www.securityfocus.com/bid/103947","name":"103947","tags":["vdb-entry","x_refsource_BID"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-119","description":"Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","dateUpdated":"2018-05-05T09:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6"},"datePublic":"2018-04-17T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2018-04-17T00:00:00","ID":"CVE-2018-7522","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Triconex Tricon","version":{"version_data":[{"version_value":"MP model 3008 firmware versions 10.0-10.4"}]}}]},"vendor_name":"Schneider Electric"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Improper Restriction Of Operations Within The Bounds Of A Memory Buffer CWE-119"}]}]},"references":{"reference_data":[{"name":"https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/","refsource":"CONFIRM","url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02"},{"name":"103947","refsource":"BID","url":"http://www.securityfocus.com/bid/103947"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://www.securityfocus.com/bid/103947","name":"103947","tags":["vdb-entry","x_refsource_BID","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T06:31:04.336Z"}}]}}}