{"id":"CVE-2018-14787","state":"PUBLISHED","title":"In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders whi","description":"In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions.","publishedAt":"2018-08-22T18:00:00.000Z","updatedAt":"2024-09-16T18:59:28.155Z","severity":null,"assigner":"icscert","products":["Philips IntelliSpace Cardiovascular (ISCV) products"],"affected":[{"vendor":"Philips","product":"IntelliSpace Cardiovascular (ISCV) products","versions":[{"version":"IntelliSpace Cardiovascular, Version 3.1 or prior","status":"affected"},{"version":"Xcelera Version 4.1 or prior","status":"affected"}]}],"references":["https://www.usa.philips.com/healthcare/about/customer-support/product-security","https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"],"weaknesses":["CWE-269"],"ingestedAt":"2026-10-29T19:44:20.464Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2018/14xxx/CVE-2018-14787.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2018-14787","state":"PUBLISHED","datePublished":"2018-08-22T18:00:00.000Z","dateUpdated":"2024-09-16T18:59:28.155Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2018-08-01T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions."}],"affected":[{"vendor":"Philips","product":"IntelliSpace Cardiovascular (ISCV) products","versions":[{"version":"IntelliSpace Cardiovascular, Version 3.1 or prior","status":"affected"},{"version":"Xcelera Version 4.1 or prior","status":"affected"}]}],"references":[{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","tags":["x_refsource_CONFIRM"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-269","description":"IMPROPER PRIVILEGE MANAGEMENT CWE-269","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","dateUpdated":"2018-08-22T17:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6"},"datePublic":"2018-08-14T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","DATE_PUBLIC":"2018-08-14T00:00:00","ID":"CVE-2018-14787","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"IntelliSpace Cardiovascular (ISCV) products","version":{"version_data":[{"version_value":"IntelliSpace Cardiovascular, Version 3.1 or prior"},{"version_value":"Xcelera Version 4.1 or prior"}]}}]},"vendor_name":"Philips"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges could access folders which contain executables where authenticated users have write permissions, and could then execute arbitrary code with local administrative permissions."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"IMPROPER PRIVILEGE MANAGEMENT CWE-269"}]}]},"references":{"reference_data":[{"name":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","refsource":"CONFIRM","url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-226-01","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T09:38:13.911Z"}}]}}}