{"id":"CVE-2018-13814","state":"PUBLISHED","title":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V14), SIMATIC HMI KTP M","description":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.","publishedAt":"2018-12-13T16:00:00.000Z","updatedAt":"2024-08-05T09:14:47.244Z","severity":null,"assigner":"siemens","products":["Siemens AG SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)"],"affected":[{"vendor":"Siemens AG","product":"SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","versions":[{"version":"SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V14","status":"affected"},{"version":"SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V14","status":"affected"},{"version":"SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14","status":"affected"},{"version":"SIMATIC WinCC Runtime Advanced : All versions < V14","status":"affected"},{"version":"SIMATIC WinCC Runtime Professional : All versions < V14","status":"affected"},{"version":"SIMATIC WinCC (TIA Portal) : All versions < V14","status":"affected"},{"version":"SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions","status":"affected"}]}],"references":["http://www.securityfocus.com/bid/105931","https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf"],"weaknesses":["CWE-113"],"ingestedAt":"2026-10-29T19:44:17.855Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2018/13xxx/CVE-2018-13814.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2018-13814","state":"PUBLISHED","datePublished":"2018-12-13T16:00:00.000Z","dateUpdated":"2024-08-05T09:14:47.244Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2018-07-10T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."}],"affected":[{"vendor":"Siemens AG","product":"SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","versions":[{"version":"SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V14","status":"affected"},{"version":"SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V14","status":"affected"},{"version":"SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14","status":"affected"},{"version":"SIMATIC WinCC Runtime Advanced : All versions < V14","status":"affected"},{"version":"SIMATIC WinCC Runtime Professional : All versions < V14","status":"affected"},{"version":"SIMATIC WinCC (TIA Portal) : All versions < V14","status":"affected"},{"version":"SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions","status":"affected"}]}],"references":[{"url":"http://www.securityfocus.com/bid/105931","name":"105931","tags":["vdb-entry","x_refsource_BID"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf","tags":["x_refsource_CONFIRM"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-113","description":"CWE-113: Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","dateUpdated":"2018-12-14T10:57:02.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77"},"datePublic":"2018-12-13T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2018-13814","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" & 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","version":{"version_data":[{"version_value":"SIMATIC HMI Comfort Panels 4\" - 22\" : All versions < V14"},{"version_value":"SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" : All versions < V14"},{"version_value":"SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F : All versions < V14"},{"version_value":"SIMATIC WinCC Runtime Advanced : All versions < V14"},{"version_value":"SIMATIC WinCC Runtime Professional : All versions < V14"},{"version_value":"SIMATIC WinCC (TIA Portal) : All versions < V14"},{"version_value":"SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) : All versions"}]}}]},"vendor_name":"Siemens AG"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-113: Improper Neutralization of CRLF Sequences in HTTP Headers ('HTTP Response Splitting')"}]}]},"references":{"reference_data":[{"name":"105931","refsource":"BID","url":"http://www.securityfocus.com/bid/105931"},{"name":"https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf","refsource":"CONFIRM","url":"https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"http://www.securityfocus.com/bid/105931","name":"105931","tags":["vdb-entry","x_refsource_BID","x_transferred"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T09:14:47.244Z"}}]}}}