{"id":"CVE-2017-9629","state":"PUBLISHED","title":"A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerabil","description":"A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.","publishedAt":"2017-07-07T17:00:00.000Z","updatedAt":"2024-08-05T17:11:02.286Z","severity":null,"assigner":"icscert","products":["n/a Schneider Electric Wonderware ArchestrA Logger"],"affected":[{"vendor":"n/a","product":"Schneider Electric Wonderware ArchestrA Logger","versions":[{"version":"Schneider Electric Wonderware ArchestrA Logger","status":"affected"}]}],"references":["http://www.securityfocus.com/bid/99488","https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04","http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/","http://www.securitytracker.com/id/1038836"],"weaknesses":["CWE-121"],"ingestedAt":"2026-10-29T19:44:00.786Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2017/9xxx/CVE-2017-9629.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2017-9629","state":"PUBLISHED","datePublished":"2017-07-07T17:00:00.000Z","dateUpdated":"2024-08-05T17:11:02.286Z","assignerShortName":"icscert","assignerOrgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6","dateReserved":"2017-06-14T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account."}],"affected":[{"vendor":"n/a","product":"Schneider Electric Wonderware ArchestrA Logger","versions":[{"version":"Schneider Electric Wonderware ArchestrA Logger","status":"affected"}]}],"references":[{"url":"http://www.securityfocus.com/bid/99488","name":"99488","tags":["vdb-entry","x_refsource_BID"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04","tags":["x_refsource_MISC"]},{"url":"http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/","tags":["x_refsource_MISC"]},{"url":"http://www.securitytracker.com/id/1038836","name":"1038836","tags":["vdb-entry","x_refsource_SECTRACK"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-121","description":"CWE-121","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"icscert","dateUpdated":"2017-07-11T09:57:01.000Z","orgId":"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6"},"datePublic":"2017-07-07T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"ics-cert@hq.dhs.gov","ID":"CVE-2017-9629","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"Schneider Electric Wonderware ArchestrA Logger","version":{"version_data":[{"version_value":"Schneider Electric Wonderware ArchestrA Logger"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-121"}]}]},"references":{"reference_data":[{"name":"99488","refsource":"BID","url":"http://www.securityfocus.com/bid/99488"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04"},{"name":"http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/","refsource":"MISC","url":"http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/"},{"name":"1038836","refsource":"SECTRACK","url":"http://www.securitytracker.com/id/1038836"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"http://www.securityfocus.com/bid/99488","name":"99488","tags":["vdb-entry","x_refsource_BID","x_transferred"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://www.securitytracker.com/id/1038836","name":"1038836","tags":["vdb-entry","x_refsource_SECTRACK","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T17:11:02.286Z"}}]}}}