{"id":"CVE-2017-7971","state":"PUBLISHED","title":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that al","description":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the use of outdated cipher suites and improper verification of peer SSL Certificate.","publishedAt":"2017-09-25T19:00:00.000Z","updatedAt":"2024-09-16T22:15:34.585Z","severity":null,"assigner":"schneider","products":["Schneider Electric SE PowerSCADA Anywhere","Schneider Electric SE Citect Anywhere"],"affected":[{"vendor":"Schneider Electric SE","product":"PowerSCADA Anywhere","versions":[{"version":"Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2","status":"affected"}]},{"vendor":"Schneider Electric SE","product":"Citect Anywhere","versions":[{"version":"version 1.0","status":"affected"}]}],"references":["http://www.securityfocus.com/bid/99913","https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"],"weaknesses":[],"ingestedAt":"2026-10-29T19:43:54.997Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2017/7xxx/CVE-2017-7971.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2017-7971","state":"PUBLISHED","datePublished":"2017-09-25T19:00:00.000Z","dateUpdated":"2024-09-16T22:15:34.585Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2017-04-19T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the use of outdated cipher suites and improper verification of peer SSL Certificate."}],"affected":[{"vendor":"Schneider Electric SE","product":"PowerSCADA Anywhere","versions":[{"version":"Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2","status":"affected"}]},{"vendor":"Schneider Electric SE","product":"Citect Anywhere","versions":[{"version":"version 1.0","status":"affected"}]}],"references":[{"url":"http://www.securityfocus.com/bid/99913","name":"99913","tags":["vdb-entry","x_refsource_BID"]},{"url":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","tags":["x_refsource_CONFIRM"]},{"url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/","tags":["x_refsource_CONFIRM"]}],"problemTypes":[{"descriptions":[{"description":"Improper Validaiton of Certificate Expiration","lang":"en","type":"text"}]}],"providerMetadata":{"shortName":"schneider","dateUpdated":"2017-09-26T09:57:01.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb"},"datePublic":"2017-06-22T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","DATE_PUBLIC":"2017-06-22T00:00:00","ID":"CVE-2017-7971","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"PowerSCADA Anywhere","version":{"version_data":[{"version_value":"Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"}]}},{"product_name":"Citect Anywhere","version":{"version_data":[{"version_value":"version 1.0"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the use of outdated cipher suites and improper verification of peer SSL Certificate."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Improper Validaiton of Certificate Expiration"}]}]},"references":{"reference_data":[{"name":"99913","refsource":"BID","url":"http://www.securityfocus.com/bid/99913"},{"name":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","refsource":"CONFIRM","url":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"},{"name":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/","refsource":"CONFIRM","url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"http://www.securityfocus.com/bid/99913","name":"99913","tags":["vdb-entry","x_refsource_BID","x_transferred"]},{"url":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T16:19:29.449Z"}}]}}}