{"id":"CVE-2017-7970","state":"PUBLISHED","title":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that al","description":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components.","publishedAt":"2017-09-25T19:00:00.000Z","updatedAt":"2024-09-17T02:56:33.769Z","severity":null,"assigner":"schneider","products":["Schneider Electric SE PowerSCADA Anywhere","Schneider Electric SE Citect Anywhere"],"affected":[{"vendor":"Schneider Electric SE","product":"PowerSCADA Anywhere","versions":[{"version":"Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2","status":"affected"}]},{"vendor":"Schneider Electric SE","product":"Citect Anywhere","versions":[{"version":"version 1.0","status":"affected"}]}],"references":["http://www.securityfocus.com/bid/99913","https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"],"weaknesses":[],"ingestedAt":"2026-10-29T19:43:54.997Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2017/7xxx/CVE-2017-7970.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2017-7970","state":"PUBLISHED","datePublished":"2017-09-25T19:00:00.000Z","dateUpdated":"2024-09-17T02:56:33.769Z","assignerShortName":"schneider","assignerOrgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb","dateReserved":"2017-04-19T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components."}],"affected":[{"vendor":"Schneider Electric SE","product":"PowerSCADA Anywhere","versions":[{"version":"Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2","status":"affected"}]},{"vendor":"Schneider Electric SE","product":"Citect Anywhere","versions":[{"version":"version 1.0","status":"affected"}]}],"references":[{"url":"http://www.securityfocus.com/bid/99913","name":"99913","tags":["vdb-entry","x_refsource_BID"]},{"url":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","tags":["x_refsource_CONFIRM"]},{"url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/","tags":["x_refsource_CONFIRM"]}],"problemTypes":[{"descriptions":[{"description":"Information Exposure","lang":"en","type":"text"}]}],"providerMetadata":{"shortName":"schneider","dateUpdated":"2017-09-26T09:57:01.000Z","orgId":"076d1eb6-cfab-4401-b34d-6dfc2a413bdb"},"datePublic":"2017-06-22T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cybersecurity@schneider-electric.com","DATE_PUBLIC":"2017-06-22T00:00:00","ID":"CVE-2017-7970","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"PowerSCADA Anywhere","version":{"version_data":[{"version_value":"Version 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2"}]}},{"product_name":"Citect Anywhere","version":{"version_data":[{"version_value":"version 1.0"}]}}]},"vendor_name":"Schneider Electric SE"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"Information Exposure"}]}]},"references":{"reference_data":[{"name":"99913","refsource":"BID","url":"http://www.securityfocus.com/bid/99913"},{"name":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","refsource":"CONFIRM","url":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere"},{"name":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/","refsource":"CONFIRM","url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"http://www.securityfocus.com/bid/99913","name":"99913","tags":["vdb-entry","x_refsource_BID","x_transferred"]},{"url":"https://www.citect.schneider-electric.com/safety-and-security-central/36-security-notifications/9071-security-notification-citect-anywhere","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-173-01/","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T16:19:29.484Z"}}]}}}