{"id":"CVE-2017-2682","state":"PUBLISHED","title":"The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allo","description":"The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allowing an attacker to execute administrative operations, provided the targeted user has an active session and is induced to trigger a malicious request.","publishedAt":"2017-02-27T11:00:00.000Z","updatedAt":"2024-08-05T14:02:07.157Z","severity":null,"assigner":"siemens","products":["n/a RUGGEDCOM NMS All versions < V2.1 (Windows and Linux)"],"affected":[{"vendor":"n/a","product":"RUGGEDCOM NMS All versions < V2.1 (Windows and Linux)","versions":[{"version":"RUGGEDCOM NMS All versions < V2.1 (Windows and Linux)","status":"affected"}]}],"references":["http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-363881.pdf","https://ics-cert.us-cert.gov/advisories/ICSA-17-059-01","http://www.securitytracker.com/id/1037958","http://www.securityfocus.com/bid/96458"],"weaknesses":["CWE-352"],"ingestedAt":"2026-10-29T19:43:39.462Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2017/2xxx/CVE-2017-2682.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2017-2682","state":"PUBLISHED","datePublished":"2017-02-27T11:00:00.000Z","dateUpdated":"2024-08-05T14:02:07.157Z","assignerShortName":"siemens","assignerOrgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77","dateReserved":"2016-12-01T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allowing an attacker to execute administrative operations, provided the targeted user has an active session and is induced to trigger a malicious request."}],"affected":[{"vendor":"n/a","product":"RUGGEDCOM NMS All versions < V2.1 (Windows and Linux)","versions":[{"version":"RUGGEDCOM NMS All versions < V2.1 (Windows and Linux)","status":"affected"}]}],"references":[{"url":"http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-363881.pdf","tags":["x_refsource_CONFIRM"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-059-01","tags":["x_refsource_MISC"]},{"url":"http://www.securitytracker.com/id/1037958","name":"1037958","tags":["vdb-entry","x_refsource_SECTRACK"]},{"url":"http://www.securityfocus.com/bid/96458","name":"96458","tags":["vdb-entry","x_refsource_BID"]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-352","description":"CWE-352: Cross-Site Request Forgery (CSRF)","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"siemens","dateUpdated":"2017-07-14T09:57:01.000Z","orgId":"cec7a2ec-15b4-4faf-bd53-b40f371f3a77"},"datePublic":"2017-02-27T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"productcert@siemens.com","ID":"CVE-2017-2682","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"RUGGEDCOM NMS All versions < V2.1 (Windows and Linux)","version":{"version_data":[{"version_value":"RUGGEDCOM NMS All versions < V2.1 (Windows and Linux)"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allowing an attacker to execute administrative operations, provided the targeted user has an active session and is induced to trigger a malicious request."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"CWE-352: Cross-Site Request Forgery (CSRF)"}]}]},"references":{"reference_data":[{"name":"http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-363881.pdf","refsource":"CONFIRM","url":"http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-363881.pdf"},{"name":"https://ics-cert.us-cert.gov/advisories/ICSA-17-059-01","refsource":"MISC","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-059-01"},{"name":"1037958","refsource":"SECTRACK","url":"http://www.securitytracker.com/id/1037958"},{"name":"96458","refsource":"BID","url":"http://www.securityfocus.com/bid/96458"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-363881.pdf","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-059-01","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://www.securitytracker.com/id/1037958","name":"1037958","tags":["vdb-entry","x_refsource_SECTRACK","x_transferred"]},{"url":"http://www.securityfocus.com/bid/96458","name":"96458","tags":["vdb-entry","x_refsource_BID","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T14:02:07.157Z"}}]}}}