{"id":"CVE-2017-17199","state":"PUBLISHED","title":"Huawei DP300 V500R002C00; RP200 V500R002C00; V600R006C00; TE30 V100R001C10; V500R002C00; V600R006C00; TE40 V500R002C00; V600R006C00; TE50 V500R002C00; V600R006C00; TE60 V100R001C10","description":"Huawei DP300 V500R002C00; RP200 V500R002C00; V600R006C00; TE30 V100R001C10; V500R002C00; V600R006C00; TE40 V500R002C00; V600R006C00; TE50 V500R002C00; V600R006C00; TE60 V100R001C10; V500R002C00; V600R006C00 have an out-of-bounds read vulnerability due to the improper processing of malformed H323 messages. A remote attacker that controls a server could exploit this vulnerability by sending malformed H323 reply messages to a target device. Successful exploit could make the device read out of bounds and probably make a service unavailable.","publishedAt":"2018-03-09T17:00:00.000Z","updatedAt":"2024-08-05T20:43:59.855Z","severity":null,"assigner":"huawei","products":["Huawei Technologies Co., Ltd. DP300; RP200; TE30; TE40; TE50; TE60"],"affected":[{"vendor":"Huawei Technologies Co., Ltd.","product":"DP300; RP200; TE30; TE40; TE50; TE60","versions":[{"version":"DP300 V500R002C00","status":"affected"},{"version":"RP200 V500R002C00","status":"affected"},{"version":"V600R006C00","status":"affected"},{"version":"TE30 V100R001C10","status":"affected"},{"version":"V500R002C00","status":"affected"},{"version":"TE40 V500R002C00","status":"affected"},{"version":"TE50 V500R002C00","status":"affected"},{"version":"TE60 V100R001C10","status":"affected"}]}],"references":["http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180207-03-h323-en"],"weaknesses":[],"ingestedAt":"2026-10-29T19:43:28.887Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2017/17xxx/CVE-2017-17199.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2017-17199","state":"PUBLISHED","datePublished":"2018-03-09T17:00:00.000Z","dateUpdated":"2024-08-05T20:43:59.855Z","assignerShortName":"huawei","assignerOrgId":"25ac1063-e409-4190-8079-24548c77ea2e","dateReserved":"2017-12-04T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Huawei DP300 V500R002C00; RP200 V500R002C00; V600R006C00; TE30 V100R001C10; V500R002C00; V600R006C00; TE40 V500R002C00; V600R006C00; TE50 V500R002C00; V600R006C00; TE60 V100R001C10; V500R002C00; V600R006C00 have an out-of-bounds read vulnerability due to the improper processing of malformed H323 messages. A remote attacker that controls a server could exploit this vulnerability by sending malformed H323 reply messages to a target device. Successful exploit could make the device read out of bounds and probably make a service unavailable."}],"affected":[{"vendor":"Huawei Technologies Co., Ltd.","product":"DP300; RP200; TE30; TE40; TE50; TE60","versions":[{"version":"DP300 V500R002C00","status":"affected"},{"version":"RP200 V500R002C00","status":"affected"},{"version":"V600R006C00","status":"affected"},{"version":"TE30 V100R001C10","status":"affected"},{"version":"V500R002C00","status":"affected"},{"version":"TE40 V500R002C00","status":"affected"},{"version":"TE50 V500R002C00","status":"affected"},{"version":"TE60 V100R001C10","status":"affected"}]}],"references":[{"url":"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180207-03-h323-en","tags":["x_refsource_CONFIRM"]}],"problemTypes":[{"descriptions":[{"description":"out-of-bounds read","lang":"en","type":"text"}]}],"providerMetadata":{"shortName":"huawei","dateUpdated":"2018-03-09T16:57:01.000Z","orgId":"25ac1063-e409-4190-8079-24548c77ea2e"},"datePublic":"2018-02-07T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"psirt@huawei.com","ID":"CVE-2017-17199","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"DP300; RP200; TE30; TE40; TE50; TE60","version":{"version_data":[{"version_value":"DP300 V500R002C00"},{"version_value":"RP200 V500R002C00"},{"version_value":"V600R006C00"},{"version_value":"TE30 V100R001C10"},{"version_value":"V500R002C00"},{"version_value":"V600R006C00"},{"version_value":"TE40 V500R002C00"},{"version_value":"V600R006C00"},{"version_value":"TE50 V500R002C00"},{"version_value":"V600R006C00"},{"version_value":"TE60 V100R001C10"},{"version_value":"V500R002C00"},{"version_value":"V600R006C00"}]}}]},"vendor_name":"Huawei Technologies Co., Ltd."}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Huawei DP300 V500R002C00; RP200 V500R002C00; V600R006C00; TE30 V100R001C10; V500R002C00; V600R006C00; TE40 V500R002C00; V600R006C00; TE50 V500R002C00; V600R006C00; TE60 V100R001C10; V500R002C00; V600R006C00 have an out-of-bounds read vulnerability due to the improper processing of malformed H323 messages. A remote attacker that controls a server could exploit this vulnerability by sending malformed H323 reply messages to a target device. Successful exploit could make the device read out of bounds and probably make a service unavailable."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"out-of-bounds read"}]}]},"references":{"reference_data":[{"name":"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180207-03-h323-en","refsource":"CONFIRM","url":"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180207-03-h323-en"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180207-03-h323-en","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-05T20:43:59.855Z"}}]}}}