{"id":"CVE-2013-1661","state":"PUBLISHED","title":"VMware ESXi 4.0 through 5.1, and ESX 4.0 and 4.1, does not properly implement the Network File Copy (NFC) protocol, which allows man-in-the-middle attackers to cause a denial of se","description":"VMware ESXi 4.0 through 5.1, and ESX 4.0 and 4.1, does not properly implement the Network File Copy (NFC) protocol, which allows man-in-the-middle attackers to cause a denial of service (unhandled exception and application crash) by modifying the client-server data stream.","publishedAt":"2013-09-04T01:00:00.000Z","updatedAt":"2024-09-16T17:08:49.716Z","severity":null,"assigner":"mitre","products":["n/a n/a"],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":["http://www.vmware.com/security/advisories/VMSA-2013-0011.html"],"weaknesses":[],"ingestedAt":"2026-10-29T19:40:38.921Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2013/1xxx/CVE-2013-1661.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2013-1661","state":"PUBLISHED","datePublished":"2013-09-04T01:00:00.000Z","dateUpdated":"2024-09-16T17:08:49.716Z","assignerShortName":"mitre","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateReserved":"2013-02-12T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"VMware ESXi 4.0 through 5.1, and ESX 4.0 and 4.1, does not properly implement the Network File Copy (NFC) protocol, which allows man-in-the-middle attackers to cause a denial of service (unhandled exception and application crash) by modifying the client-server data stream."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"http://www.vmware.com/security/advisories/VMSA-2013-0011.html","tags":["x_refsource_CONFIRM"]}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"shortName":"mitre","dateUpdated":"2013-09-04T01:00:00.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca"},"x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2013-1661","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"VMware ESXi 4.0 through 5.1, and ESX 4.0 and 4.1, does not properly implement the Network File Copy (NFC) protocol, which allows man-in-the-middle attackers to cause a denial of service (unhandled exception and application crash) by modifying the client-server data stream."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"http://www.vmware.com/security/advisories/VMSA-2013-0011.html","refsource":"CONFIRM","url":"http://www.vmware.com/security/advisories/VMSA-2013-0011.html"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"http://www.vmware.com/security/advisories/VMSA-2013-0011.html","tags":["x_refsource_CONFIRM","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-06T15:13:32.810Z"}}]}}}