{"id":"CVE-2013-10058","state":"PUBLISHED","title":"Linksys Routers apply.cgi Remote Command Injection","description":"An authenticated OS command injection vulnerability exists in various Linksys router models (tested on WRT160Nv2) running firmware version v2.0.03 via the apply.cgi endpoint. The web interface fails to properly sanitize user-supplied input passed to the ping_size parameter during diagnostic operations. An attacker with valid credentials can inject arbitrary shell commands, enabling remote code execution.","publishedAt":"2025-08-01T20:44:51.202Z","updatedAt":"2026-04-07T14:03:12.433Z","severity":{"score":8.6,"label":"High","version":"4.0","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","source":"VulnCheck"},"assigner":"VulnCheck","products":["Linksys WRT160nv2"],"affected":[{"vendor":"Linksys","product":"WRT160nv2","defaultStatus":"unknown","versions":[{"version":"2.0.03","status":"affected"}],"modules":["apply.cgi"]}],"references":["https://raw.githubusercontent.com/rapid7/metasploit-framework/master/modules/exploits/linux/http/linksys_wrt160nv2_apply_exec.rb","https://www.exploit-db.com/exploits/24478","https://www.exploit-db.com/exploits/25608","https://web.archive.org/web/20140830181242/http://www.s3cur1ty.de/m1adv2013-012","https://www.vulncheck.com/advisories/linksys-legacy-routers-remote-command-injection"],"weaknesses":["CWE-78"],"ingestedAt":"2026-10-29T19:40:36.859Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2013/10xxx/CVE-2013-10058.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.2","cveMetadata":{"cveId":"CVE-2013-10058","state":"PUBLISHED","datePublished":"2025-08-01T20:44:51.202Z","dateUpdated":"2026-04-07T14:03:12.433Z","assignerShortName":"VulnCheck","assignerOrgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","dateReserved":"2025-08-01T16:47:00.729Z"},"containers":{"cna":{"title":"Linksys Routers apply.cgi Remote Command Injection","descriptions":[{"lang":"en","value":"An authenticated OS command injection vulnerability exists in various Linksys router models (tested on WRT160Nv2) running firmware version v2.0.03 via the apply.cgi endpoint. The web interface fails to properly sanitize user-supplied input passed to the ping_size parameter during diagnostic operations. An attacker with valid credentials can inject arbitrary shell commands, enabling remote code execution."}],"affected":[{"vendor":"Linksys","product":"WRT160nv2","defaultStatus":"unknown","versions":[{"version":"2.0.03","status":"affected"}],"modules":["apply.cgi"]}],"references":[{"url":"https://raw.githubusercontent.com/rapid7/metasploit-framework/master/modules/exploits/linux/http/linksys_wrt160nv2_apply_exec.rb","tags":["exploit"]},{"url":"https://www.exploit-db.com/exploits/24478","tags":["exploit"]},{"url":"https://www.exploit-db.com/exploits/25608","tags":["exploit"]},{"url":"https://web.archive.org/web/20140830181242/http://www.s3cur1ty.de/m1adv2013-012","tags":["technical-description","exploit"]},{"url":"https://www.vulncheck.com/advisories/linksys-legacy-routers-remote-command-injection","tags":["third-party-advisory"]}],"metrics":[{"cvssV4_0":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","baseScore":8.6,"baseSeverity":"HIGH","exploitMaturity":"NOT_DEFINED","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"format":"CVSS","scenarios":[{"lang":"en","value":"GENERAL"}]}],"problemTypes":[{"descriptions":[{"cweId":"CWE-78","description":"CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')","lang":"en","type":"CWE"}]}],"providerMetadata":{"shortName":"VulnCheck","orgId":"83251b91-4cc7-4094-a5c7-464a1b83ea10","dateUpdated":"2026-04-07T14:03:12.433Z"},"cpeApplicability":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:linksys:wrt160nl:2.0.03:*:*:*:*:*:*:*","vulnerable":true}],"negate":false,"operator":"OR"}],"operator":"OR"}],"credits":[{"lang":"en","type":"finder","value":"Michael Messner"}],"impacts":[{"capecId":"CAPEC-88","descriptions":[{"lang":"en","value":"CAPEC-88 OS Command Injection"}]}],"source":{"discovery":"UNKNOWN"},"tags":["unsupported-when-assigned"],"x_generator":{"engine":"Vulnogram 0.2.0"},"datePublic":"2013-02-11T00:00:00.000Z"},"adp":[{"title":"CISA ADP Vulnrichment","references":[{"url":"https://raw.githubusercontent.com/rapid7/metasploit-framework/master/modules/exploits/linux/http/linksys_wrt160nv2_apply_exec.rb","tags":["exploit"]},{"url":"https://www.exploit-db.com/exploits/24478","tags":["exploit"]},{"url":"https://www.exploit-db.com/exploits/25608","tags":["exploit"]},{"url":"https://web.archive.org/web/20140830181242/http://www.s3cur1ty.de/m1adv2013-012","tags":["exploit"]}],"metrics":[{"other":{"type":"ssvc","content":{"timestamp":"2025-08-06T14:06:01.817359Z","id":"CVE-2013-10058","options":[{"Exploitation":"poc"},{"Automatable":"yes"},{"Technical Impact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}}],"providerMetadata":{"shortName":"CISA-ADP","orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","dateUpdated":"2025-08-06T14:06:06.771Z"}}]}}}