{"id":"CVE-2010-2772","state":"PUBLISHED","title":"Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in ","description":"Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.","publishedAt":"2010-07-22T10:00:00.000Z","updatedAt":"2024-08-07T02:46:48.161Z","severity":null,"assigner":"mitre","products":["n/a n/a"],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":["https://exchange.xforce.ibmcloud.com/vulnerabilities/60587","http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr","http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c","http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01","http://www.f-secure.com/weblog/archives/00001987.html","http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1","http://www.vupen.com/english/advisories/2010/1893","http://secunia.com/advisories/40682","http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/","http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx","http://www.securityfocus.com/bid/41753","http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725","http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22","http://www.wired.com/threatlevel/2010/07/siemens-scada/"],"weaknesses":[],"ingestedAt":"2026-10-29T19:39:40.033Z","source":{"repository":"CVEProject/cvelistV5","path":"cves/2010/2xxx/CVE-2010-2772.json","commit":"556c9d3a8cd17e218bb8e452ba7cd619a384ff47"},"raw":{"dataType":"CVE_RECORD","dataVersion":"5.1","cveMetadata":{"cveId":"CVE-2010-2772","state":"PUBLISHED","datePublished":"2010-07-22T10:00:00.000Z","dateUpdated":"2024-08-07T02:46:48.161Z","assignerShortName":"mitre","assignerOrgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","dateReserved":"2010-07-21T00:00:00.000Z"},"containers":{"cna":{"descriptions":[{"lang":"en","value":"Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568."}],"affected":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}],"references":[{"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/60587","name":"simatic-wincc-default-password(60587)","tags":["vdb-entry","x_refsource_XF"]},{"url":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr","tags":["x_refsource_MISC"]},{"url":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c","tags":["x_refsource_CONFIRM"]},{"url":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01","tags":["x_refsource_MISC"]},{"url":"http://www.f-secure.com/weblog/archives/00001987.html","tags":["x_refsource_MISC"]},{"url":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1","tags":["x_refsource_MISC"]},{"url":"http://www.vupen.com/english/advisories/2010/1893","name":"ADV-2010-1893","tags":["vdb-entry","x_refsource_VUPEN"]},{"url":"http://secunia.com/advisories/40682","name":"40682","tags":["third-party-advisory","x_refsource_SECUNIA"]},{"url":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/","tags":["x_refsource_MISC"]},{"url":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx","tags":["x_refsource_CONFIRM"]},{"url":"http://www.securityfocus.com/bid/41753","name":"41753","tags":["vdb-entry","x_refsource_BID"]},{"url":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725","tags":["x_refsource_MISC"]},{"url":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22","tags":["x_refsource_MISC"]},{"url":"http://www.wired.com/threatlevel/2010/07/siemens-scada/","tags":["x_refsource_MISC"]}],"problemTypes":[{"descriptions":[{"description":"n/a","lang":"en","type":"text"}]}],"providerMetadata":{"shortName":"mitre","dateUpdated":"2017-08-16T14:57:01.000Z","orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca"},"datePublic":"2010-07-16T00:00:00.000Z","x_legacyV4Record":{"CVE_data_meta":{"ASSIGNER":"cve@mitre.org","ID":"CVE-2010-2772","STATE":"PUBLIC"},"affects":{"vendor":{"vendor_data":[{"product":{"product_data":[{"product_name":"n/a","version":{"version_data":[{"version_value":"n/a"}]}}]},"vendor_name":"n/a"}]}},"data_format":"MITRE","data_type":"CVE","data_version":"4.0","description":{"description_data":[{"lang":"eng","value":"Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568."}]},"problemtype":{"problemtype_data":[{"description":[{"lang":"eng","value":"n/a"}]}]},"references":{"reference_data":[{"name":"simatic-wincc-default-password(60587)","refsource":"XF","url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"},{"name":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr","refsource":"MISC","url":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"},{"name":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c","refsource":"CONFIRM","url":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c"},{"name":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01","refsource":"MISC","url":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01"},{"name":"http://www.f-secure.com/weblog/archives/00001987.html","refsource":"MISC","url":"http://www.f-secure.com/weblog/archives/00001987.html"},{"name":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1","refsource":"MISC","url":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1"},{"name":"ADV-2010-1893","refsource":"VUPEN","url":"http://www.vupen.com/english/advisories/2010/1893"},{"name":"40682","refsource":"SECUNIA","url":"http://secunia.com/advisories/40682"},{"name":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/","refsource":"MISC","url":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"},{"name":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx","refsource":"CONFIRM","url":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx"},{"name":"41753","refsource":"BID","url":"http://www.securityfocus.com/bid/41753"},{"name":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725","refsource":"MISC","url":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"},{"name":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22","refsource":"MISC","url":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22"},{"name":"http://www.wired.com/threatlevel/2010/07/siemens-scada/","refsource":"MISC","url":"http://www.wired.com/threatlevel/2010/07/siemens-scada/"}]}}},"adp":[{"title":"CVE Program Container","references":[{"url":"https://exchange.xforce.ibmcloud.com/vulnerabilities/60587","name":"simatic-wincc-default-password(60587)","tags":["vdb-entry","x_refsource_XF","x_transferred"]},{"url":"http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&c","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://www.f-secure.com/weblog/archives/00001987.html","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://www.vupen.com/english/advisories/2010/1893","name":"ADV-2010-1893","tags":["vdb-entry","x_refsource_VUPEN","x_transferred"]},{"url":"http://secunia.com/advisories/40682","name":"40682","tags":["third-party-advisory","x_refsource_SECUNIA","x_transferred"]},{"url":"http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx","tags":["x_refsource_CONFIRM","x_transferred"]},{"url":"http://www.securityfocus.com/bid/41753","name":"41753","tags":["vdb-entry","x_refsource_BID","x_transferred"]},{"url":"http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22","tags":["x_refsource_MISC","x_transferred"]},{"url":"http://www.wired.com/threatlevel/2010/07/siemens-scada/","tags":["x_refsource_MISC","x_transferred"]}],"providerMetadata":{"shortName":"CVE","orgId":"af854a3a-2127-422b-91ae-364da2661108","dateUpdated":"2024-08-07T02:46:48.161Z"}}]}}}